8kw US Split Phase Residential Hybrid Solar Inverter With High Voltage 80-400VDC
BasicSystemArchitecture
Thefollowingillustrationshowsbasicapplicationofthisinverter.
It also includes following devices to have a Complete running system.
– Generator or Utility
– PV modules
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in home or office environment, including motor type appliances such as refrigerator and air conditioner.
Mod
Inverter | GSL-8KHV-US | GSL-10KHV-US | GSL-12KHV-US |
Input (PV DC) | |||
Max. DC Input Power (W) | 10K | 12K | 15K |
Max.DCVoltage (V) |
550 |
||
Operating MPPT Voltage Range (V) | 150-500 | ||
Turn off Voltage (V) | 90 | ||
Max. DC Current per Tracker (A) | 14 | ||
N° of MPP inputs/strings per MPP input | 4/1 | ||
Max. Power per Tracker (W) | 4000 | ||
Output (AC) | |||
Rated Power (W) | 8K | 10K | 12K |
Max. AC apparent power (VA) | 8K | 10K | 12K |
Max backup outputpower (VA) | 8K | 10K | 12K |
Nominal AC voltage range (V) | 110-120/220-240Vsplit phase | ||
Nominal Frequency (Hz)* | 50/60 | ||
Frequency Range (Hz) | 45 to 54.9 / 55 to 65 | ||
Max. AC Current (A) | 32 | 42 | 47.5 |
Power Factor | 0.8 leading…0.8 lagging | ||
Total Harmonic Distortion (THD) | <2% | ||
Efficiency | |||
Max.Efficiency | 98.3% | ||
CEC Efficiency | 97.5% | ||
Max.Battery Charging/Discharging Efficiency | 95.6% | ||
MPPT Efficiency | 99.9% | ||
Loss at Standby / Loss at Night | <5W / <2W | ||
Battery | |||
BatteryType | Lifepo4 battery or Lead Acid | ||
Battery voltage range (V) DC | 80-400 | ||
Max. Charge/Discharge Current (A) | 100 | ||
Battery capacity range (kWh) | 10 to 200kwh | ||
BMS Communication Port | CAN,RS485 | ||
Protective devices | |||
Array ground insulation resistance monitoring | Integrated | ||
Ground fault monitoring/grid monitoring | Integrated | ||
Array polarity reverse protection | Integrated | ||
All-pole sensitive RCMU | Integrated | ||
Surge protection | Integrated | ||
AFCI protection | Integrated | ||
DC disconnect detection | Integrated | ||
Battery Reverse protection | Integrated | ||
Protection Class | ClassⅠ | ||
Overvoltage Category | PV Ⅱ / Mains Ⅲ | ||
General Data | |||
Dimensions (W/H/D)(mm) | 550x680x265 | ||
Weight of inverter(Kg) | 46.5 | ||
Cooling design | Natural cooling | ||
Battery/PV/AC connection | Fastening screw, or customized | ||
External transformer | Optional for off-grid mode (frequency transformer) | ||
Mounting | Wall bracket | ||
Features | |||
Display | LCD, Touch button | ||
Interface: Speedwire/Webconnect | RS485/Digital IO | ||
Operating temperature range | -25 ~ +60, derating when temperature>50℃ | ||
Communication with BMS | <30 | ||
Noise emission (dB) | High frequency isolation | ||
Topology | Natural Convection | ||
Cooling method | NEMA 3R | ||
Degree of protection inerter/battery section | <2000, derating when over 2000m | ||
Max. Altitude (above sea level) (m) | 5 years5 years5 years | ||
Maximum permissible value for relative humidity | 0 – 95%,non condensing | ||
Certificates and approvals | Can meet IEEE1547, IEEE1547.1, CSA107.1, CSA 22.2 | ||
Customized requirements | |||
Display | LCD, can be customized color LCD as required | ||
Structure cover | metal sheet + heatsink | ||
Logo | as client required | ||
Package | as client required | ||
Parallel connection | 20 pcs max,hardware interface already design inside | ||
RSD function | Optional, rapid shutdown module/function can be integrated inside | ||
SunSpec conformation | Optional, same as integrated rapid shutdown module | ||
Generator function | Optional, ATS module/function can be integrated inside to DG/GG generator | ||
Battery bank | can do match compatible with any battery brand with protocol | ||
Certificates | RoHS, ISO9001, ISO14001, ISO18001, CSA |
Power Storage-5Kw 7Kw 10Kw POWERWALL
Security
BackupProtection
Powerstoragewallisabatterythatstoresenergy,detectsoutagesandautomaticallybecomesyourhome’senergysourcewhenthegridgoesdown.Unlikegasolinegenerators,Powerstoragewallkeepsyourlightsonandphoneschargedwithoutupkeep,fuelornoise.Pairwithsolarandrechargewithsunlighttokeepyourappliancesrunningfordays.
Design
Modernand Compact
Witheasyinstallationandaminimalistdesign,Powerstoragewallcomplementsavarietyofhomestyles.Thecompact,all-in-oneconstructionfeaturesversatilemountingoptionsforindoororoutdoorspaces.
LiFePO4LithiumBatteryPackSpec | ||||||||
Energy |
Battery |
Charging Voltage |
Standard Charge Current | Max charge | Standard Discharge Current | Maximum Continuous Discharge Current |
Dimension (L×W×H) |
Weight |
5 KWH |
48V / 51.2V 100Ah |
54V / 58V |
20V/50A |
120A |
50A
|
300A(1S)
|
650*480*190mm |
53KG/58.5KG |
7 KWH |
48V / 51.2V 150Ah |
65KG/73.3KG |
||||||
10 KWH |
48V / 51.2V 200Ah |
85KG/96KG |
Max support 14 units parallel connection.
GSLENERGYisfocusedonmanufacturing,R&DandsalesforsafeLithiumbatteryandsolutions.WiththeregistrationandcertificationofCE,SGS,ROHS.Strivingtogrowintoagloballeadinglithiumbatterysupplier,GSLENERGYhasbeenworkinghardonresearchinganddevelopingnewprocesstechnologytomakeourlithiumbatterymoreaffordableandabletomeettherapidlygrowingmarketdemands.
♦ Over 500 workers in 12000 sqm2 battery cell production and pack manufacturing base.
♦Passing all certificates IEC62133, IEC62219, CE, UN38.3, MSDS, etc.
ThroughyearsdevelopmentandexperiencedinternationalsalesteaminShenzhen,GSLENERGYgreensolarandlithiumbatteryproductshavebeensoldtoclientsallovertheworld.
8kw US Split Phase Residential Hybrid Solar Inverter With High Voltage 80-400VDC
For more details and price, please send us an enquiry below ⇓⇓⇓